100% Genuine Products | Free Shipping On Order Above ₹ 3000

Waldent Obturation Pen System

Cordless Warm Vertical Compaction Device

Brand : Waldent

 10,000.00

In Stock

Wishlist
Wishlist

Waldent Obturation Pen System is a Cordless system used for Warm Vertical Compaction while doing RCT. Using Obturation Pen, one applies pressure in a vertical direction to the heat softened gutta percha and thereby causes it to flow and to fill the entire lumen of the canal.

  • Simple design
  • Convenience in application
  • Four Tips – F, FM, M, ML
  • F: #45/02, FM: #50/04, M: #55/06, ML: #55/08
  • Needle type & temperature mode can be adjusted making the gutta percha point more contact
  • Short heating time, up to 150 degrees within 2s
  • Vertical condensation technology
  • Double batteries to replace, convenient use
  • Autoclavable Tips

For Effective warm vertical Compaction

  • A continuous tapering funnel should be present from the root canal orifice to the root apex.
  • Root canal should be prepared so that it flows with the shape
  • Shape of Apical foramen should not be changed or moved.
  • Apical foramen should be kept as small as is practical so that excess gutta percha will not be forced through it during vertical compaction

Others:

  1. Variable temperature range: 160° – 240° C
  2. Internally Heated Tip & Indicator Light
  3. Powerful Battery (2800mAh)
  • 1 x Obturation Pen
  • 1 x Charging Base
  • 1 x Adaptor
  • 2 x Batteries
  • 4 x Tips (F, FM, M, ML)
  • Insert pen tip into the root canal to the point 4-7mm short of the working length and fit Endo stop in the pen tip
  • Fill the master Gutta percha cone that is dipped in a sealer
  • Place pen tip in the orifice of the canal by pressing the operation button, using the activated pen tip, cut the middle of the Gutta percha cone and the downpack it to the point 6-9mm from the APEX about 1.5 – 2 seconds only
  • Release the operation button to allow pen tip to begin cooling, while at the same time continue pushing and holding the cooled pen tip to the apex for 8 seconds to fill the canal completely. Activate the pen again by pressing and holding the operation button for about 1-1.5 seconds, compact the gutta percha cone to the point 4-7mm of working length
  • Manufacturer/Importer warranty of 6 months as applicable for this product.
  • Other Accessories (like tips, etc) are not included in the Warranty.

Reviews

There are no reviews yet

Only logged in customers who have purchased this product may leave a review.

Product You May Like

Shares
Shopping cart0
There are no products in the cart!
Continue shopping
0
Scroll to Top